Laboratory Thermometers & Hydrometers
ASTM D2726 | AS 2891.9.1 - 3 | NZS 4402:1986 | NZS 4407:2015 | NZTA M10
C300: Center 300 Digital Thermometer Type K
C301: Center 301 Dual Input K Type Thermometer Measurement Range: -200 °C to 1370 °C Resolution: 0.1 °C, 0.1 F Accuracy: ± 0.3 % of reading plus 1 °C Most of our customers like to put a good thermocouple inside their oven, reading with a digital thermometer. ITP-BK02T: 2m Type K Teflon Bead Probe c/w mini plug, is a recommended upgrade for IANZ calibration, with much improved accuracy and stability over time. For testing water temperature (tank, bath etc.) we offer an excellent immersion probe. ITP-049K06_100T2: Immersion Probe 6 x 100mm MIMS Thermocouple 1.5m PVC lead and K Type Mini Plug For asphalt testing, we offer T-handle bitumen probe for laboratory samples and convenient extra long probe for field testing, such as HMA mat on-site QC. ITP-HK08T0390: Bitumen Probe Short, K Type c/w 1m lead & T-bar Handle Stem length 390mm, tip dia. 6mm x 35mm length ITP-HK12T1000: Bitumen Probe Long, K Type c/w 1m lead & T-bar Handle Stem length 1000mm, tip dia. 5.5mm x 50mm length |
Since 1910 the name ”Ludwig Schneider“ has been synonymous with the highest quality and precision ”Made in Germany“.
Today they're one of the leading global manufacturers of high-precision measuring technology for temperature and density. The high precision of Ludwig Schneider thermometers and hydrometers is used and relied on by numerous companies all over the world. |
Hydrometers
The hydrometer is a measuring instrument used to determine the density or the specific weight of liquids. The instrument immerses into the liquid up to the point where the weight force of the displaced liquids corresponds to the weight force of the immersed body. LS hydrometers (spindle, thickness spindle, densitometer) are manufactured in accordance with national and international standards such as DIN, BS, ASTM and ISO. Each of LS instruments is carefully calibrated and are subject to strict quality control. Measurement accuracies within the tolerance limits specified by the Physical Technical Federal Institution (PTB) are complied with in the process. Depending on the intended application our hydrometers are available in an environmentally-friendly, mercury-free version, with or without integrated thermometer, with a resolution of up to 0.0001 g/cm³ and made of plastic. We gladly supply a works calibration certificate or a traceable DAkkS calibration certificate upon request. Variants: Alcoholometers | API hydrometers | Hydrometers made of plastic | For liquid gases | For mineral oils | For dairies | For must producers | For specific gravity | Hydrometers acc. to Baumé | Density hydrometers | Saccharometers | For special applications |
Glass thermometers
Glass thermometers measure precise, network-independent and cost-effective. Because by their resistance against aggressive media they are universally usable. Calibrated instruments are serving also as reference standards to monitoring further instruments. We also offer many types of glass thermometers with eco-friendly, mercury-free filling. We gladly supply a works calibration certificate or a traceable DAkkS calibration certificate upon request. Variants: ACCU-SAFE thermometers | General purpose thermometers | Laboratory thermometers | Meteorological thermometers | ASTM-IP-BS thermometers | Special thermometers |
Optris MS IR Thermometer
-32/420 °C, Resolution 0.2 °C Single laser and USB interface, MAX, MIN and HOLD functions This is a very affordable instrument for applications that require ease of use. Optris MS Plus IR Thermometer -32/530 °C, Resolution of 0.1 °C Single laser and USB interface, MAX, MIN and HOLD functions plus HIGH and LOW alarm Optris Connect Report software available Optris MS Pro Thermometer c/w Type K & Infrared Range -32 °C to 760 °C with a resolution of 0.1 °C Single laser and USB interface, MAX, MIN and HOLD functions plus HIGH and LOW alarm The emissivity is adjustable from 0.100-1.100 The included thermocouple probe allows for contact and non contact temperature measurement in one instrument. Accuracy specifications for the infrared component (20 °C...760 °C) is ±1% reading or ±1 °C whichever is greater. The accuracy of the Type K probe is not specified by the manufacturer. An IANZ certificate is available on request for all three models. |
MA-124: Dial Thermometer, 304 stainless steel case
- Range: -5° to 50°C - Accuracy: ±1% of range and division of 0.5° - 50mm dia. polycarbonate dial face & 203mm long stem - An adjustment nut allows calibration The polycarbonate dial face is not intended for use in an oven chamber. 82-D1210: Dial thermometer 0 to 60°C, 50mm dia. x 200mm long 82-D1211: Dial thermometer 0 to 100°C, 50mm dia. x 200mm long 82-D1212: Dial thermometer 0 to 200°C, 50mm dia. x 200mm long 82-D1213: Dial thermometer 0 to 260°C, 50mm dia. x 200mm long 82-D1206: Pocket dial thermometer +50 to +260°C, 45mm dia. x 150mm long 82-D1207: Pocket dial thermometer -30 to +60°C, 45mm dia. x 150mm long |